Reduction of Chemical Oxygen Demand (COD) and Ammonia (as NH3-N) concentrations of leachate from landfill drainage; using constructed wetland treatment.
Clean Rivers Trust has recently been asked to consider the use of constructed wetlands to ameliorate historic landfill leachate drainage. The main problem determinants identified to the Trust being elevated COD and Ammonia.
The treatment method of choice being constructed wetland, as it is low cost and low maintenance; with a soft footprint that can be located within the confines of such sites.
The consideration of such engineered works would be considered as part of a custom design that considers each leachate as unique; though with common characteristics across all sites of a similar operational lifespan.
The two determinants are treatable as constituent parts of leachate; wetlands, at the same time also having a beneficial effect on other contaminants. The likes of Nitrates and Phosphorus are both reduced to levels that relieve pressure on the environment. Metals also are removed, particularly easily Iron, which can clog wetland systems with hydroxides.
Three research sites known to the Trust were considered and a mean was taken as to represent the average contaminant level.