Septic tanks and treatment plants: permits and general binding rules, 2015.

Please keep your septic tank better than this picture!

1. Private Sewage Treatment,
If your house or business isn’t connected to the mains sewer, your sewage will go to one of the following:
• a septic tank – an underground tank where the solids sink to the bottom and the liquid flows out and soaks through the ground
• a small sewage treatment plant (also known as a package treatment plant) – a part-mechanical system that treats the liquid so it’s clean enough to go into a river or stream
• a cesspool (also called a cesspit) – a sealed tank that collects the sewage
• a non-standard system, eg a reed bed or a trench arch system

2. You have a septic tank or small sewage treatment plant
As the ‘operator’ of a septic tank or small sewage treatment plant you must check you meet the general binding rules. You must apply for a permit if you don’t.
You’re an operator if any of the following is true:
• you own the property that uses the system
• you own a property that shares the system with other properties – each property owner is an operator, and you’re jointly responsible for complying with the general binding rules
• you have a written agreement with the property owner that says you’re responsible for the system’s maintenance, eg you’re renting and it’s in your tenancy agreement
Contact the Environment Agency if you’re not sure whether you’re an

3. The general binding rules
You must follow the general binding rules if you’re the operator of a septic tank or small sewage treatment plant.
The sewage must:
• be domestic in nature, eg from a toilet, bathroom, shower or kitchen of a house, flat or business (eg a pub, hotel or office) – contact the Environment Agency if you’re not sure if the sewage is domestic in nature
• not cause pollution – find out how to check for pollution
There are other rules depending on whether you’re releasing this sewage:
• to the ground, eg in your back garden
• to a surface water, eg a river or stream
Ask your local installation or maintenance company if you’re not sure what sort of system you have
Releasing to the ground
You must use a septic tank or a small sewage treatment plant and a drainage field (infiltration system).
You must apply for a permit if you release (‘discharge’):
• to a well, borehole or other deep structure
• more than 2 cubic metres (2,000 litres) per day
• in a groundwater source protection zone (SPZ1)
You must also read the additional rules for discharging sewage to the ground.
Calculate how much sewage you discharge
For sewage from a residential property, use the calculator to work out how much you discharge per day.
Download ‘Daily discharge calculator for domestic properties’ (XLSX, 20KB)
For commercial properties (eg a hotel, restaurant or office) or holiday accommodation (eg a cottage or chalet), use British Water’s flows and loads guidance or contact the Environment Agency for advice.
Download ‘British Water: Flows and Loads – 4’ (PDF, 941KB)
Work out if you’re in a groundwater source protection zone 1 (SPZ1)
An SPZ1 can be either:
• the area around a commercial water supply shown on the map of protected zones – check whether your discharge is in the inner zone (Zone 1) or ask the Environment Agency
• any area within 50 metres of a private water supply for human consumption – ask your neighbours if they have a spring, well or borehole, and how far it is from your drainage field
Releasing to a surface water
You must use a small sewage treatment plant. 

You must apply for a permit if you’re discharging more than 5 cubic metres (5,000 litres) per day. Use the calculator to work out how much you discharge per day.
You must also read the additional rules for discharging sewage to a surface water.
Download ‘Daily discharge calculator for domestic properties’ (XLSX, 20KB)
For commercial properties (eg a hotel, restaurant or office) or holiday accommodation (eg a cottage or chalet), use British Water’s flows and loads guidance or contact the Environment Agency for advice.
Download ‘British Water: Flows and Loads – 4’ (PDF, 941KB)

4. Apply for a permit
You must apply for a permit if you have a septic tank or small sewage treatment plant and don’t meet the general binding rules.
Fill in the application form and choose how to pay your fee, then send it to the Environment Agency.
Before you start
You’ll need:
• the 8-figure grid reference for your septic tank or treatment plant and the point where it discharges
• to calculate the discharge – use one of the calculators in the chapter on the general binding rules
• to provide a suitable site plan – see an example site plan
Fees
Size of discharge Fee
Up to 5,000 litres (5 cubic metres) per day of domestic treated sewage £125
More than 5,000 litres (5 cubic metres) per day, or trade (non-domestic) treated sewage. There’s also an annual subsistence fee for these discharges £885
How long it takes
You should get a decision on your application within 13 weeks.
You’ll be told if your application may take longer, eg because of planning issues.
Your application is refused
If your application is refused, you’ll be told:
• the reasons for refusal
• how you can appeal
Complying with your permit
See the guidance on how to comply with your permit, including maintenance, record keeping and pollution reporting requirements.
Get help
You can ask Environment Agency.

5. You have a cesspool
You don’t have to comply with the general binding rules or apply for a permit – but you must have planning permission and building regulations approval to install a new cesspool.
You must have it regularly emptied by a registered waste carrier..
You must make sure it doesn’t leak or overflow as this will pollute the environment. The Environment Agency can require you to repair or replace your cesspool if it’s in poor condition.

Note.

Clean Rivers Trust agrees with these regulations and best practice and if for any reason you might be unsure regarding any aspect of the regulations talk to the Environment Agency.

Clean Rivers Trust December 2015